Standard
Performance
Features:
Standard-Capacity-1/3
hp, 30 lbs Ice Bank, Flooded Standard Performance
manifold
Stainless Steel Cabinet, Water bath, Product Lines
and Splash Plate; removable Refrigeration Deck
Insulation 100% Non-CFC-Structural Foam
Flex Manifold Configuration for Multiple
Non-Carbonated Drinks
Available with 5 or 6 Post-Mix Dispensing Valves
100% Non-CFC, R134A Refrigerant
Optional Lighted Marquee Kit and Leg Kit
Specifications:
Shipping
weight:approximately 150 lbs ( 68.04 kg)
Counter weight with water: approximately 220 lbs (
99.79 kg)
Electrical Ratings: 115 V, 60 Hz, 6.5 A
Optional 230 V, 50 Hz, 1 phase, 4.4 A
UL grounded line, cord, and plug
Compressor: 1/3 hp
Agitator Motor: 25 W
Ice Bank Control: Ranco 018-113-00, Pre-set
Transformer: 24 VAC Secondary
Fittings: Stainless steel inlet labeled, 1/4"
barb syrup, 3/8" barb soda
Valves available: LEV® standard
PN
85-1595A-100 5 LEV®(Manifold
configuration:3, 2 flex with 4 and 5 optional water
options)
PN 85-1596A-100 6LEV®(Manifold
configuration:3, 3flex with 4,5 and 6optional water
options)
DRAW
PERFORMANCE
Number of Drinks Below 40°F (4.5°C)
75°F(24°C)
ambient Temperature
| 2-12 oz./min.: |
350 |
| 4-12 oz./min.: |
190 |
90°F(32°C)
ambient Temperature
| 2-12 oz./min.: |
180 |
| 4-12 oz./min.: |
90 |
REFRIGERATION
CAPACITY: When supplied with a 75°F(24°C)
incoming water, 75°(24°C) syrup and with room
temperature at , the unit will dispense 350 twelve
ounce drinks at a temperature at 40°F(4.5°C) or
below, drawn at the rate of 2 drinks per minute.
Full recovery of the ice bank requires about 2.9
hours. Ice bank weight: 30lbs.
Agency
Approvals:

|